Installation manual
©2008 McQuay International 
2
1 General Introduction 
    MDS(Multi-Digital Scroll) units are most suitable for commercial building,  office room, hotel, which includes the outdoor units and multi- 
indoor  units;  The  most  advantage  of  this  product  range  is  unconventional  outdoor units  with digital  scroll  compressor, To  meet  different 
requirements, there are many indoor units for options: ceiling concealed indoor units, ceiling cassette indoors units and ceiling duct indoor units, 
When indoors are ceiling duct type, if there is a special requirement, the indoor units can add the electrical heater and steam coil to extend the 
heating capacity. 
●  Outdoor Units: MDS-B Series 
        Product  Range:  MDS080B(R)5、 MDS100B(R)5、MDS120B(R)5、 MDS140B(R)5、MDS160B(R)5、 MDS180B(R)5、MDS200B(R)5、
MDS220B(R)5、MDS240B(R)5、MDS260B(R)5、MDS280B(R)5  、MDS300B(R)5、MDS320B(R)5、MDS340B(R)5、MDS360B(R)5、MDS380B(R)5、
MDS400B(R)5、MDS420B(R)5、MDS440B(R)5、MDS460B(R)5、MDS480B(R)5、MDS500B(R)5 
        Feature: The outdoor units are designed that the return air from front and back side panel and vertical air discharge. Units are compact, and 
elegant design with low noise; the compressor is with advanced technology of digital scroll, can meet the stageless energy level adjustment from 
10% to 100%. 
        Nomenclature:
●  Ceiling Concealed Indoor Units:
::
:MCC-TP Series 
        Product Range: MCC009TP、MCC011TP、MCC015TP、MCC018TP、MCC020TP、MCC028TP、MCC032TP、MCC035TP、MCC045TP、
MCC050TP、MCC060TP 
        Feature: Concealed type, space saving, ESP is optional. 
Nomenclature:
  ●  Ceiling Cassette Indoor Units:
::
:MCK-UP/TP Series 
         Product Range: MCK011UP、MCK015UP、MCK018UP、MCK020UP、MCK028TP、MCK032TP、MCK035TP、MCK045TP、MCK050TP、
MCK060TP 
         Feature: 4 ways air supply evenly, streamlined design, in-build high efficiency filter. 
         Nomenclature: 
Cooling capacity No.300 means 30HP
Power supply features F: 380-415V/3N~/50Hz; P: 208-230V/3~/60Hz
McQuay multi digital 
scroll unit
Heat pump (omitted if cooling only)
Applied region Omitted: China, B: Australia, U: America, E: Other region.
Combined feature of unit M: master unit, S: slave unit; 
Single or total combined unit: Omitted
MDS 300 B R M 5 -F AB
 E 
Design serial No.
Description of the unit
For R410A refrigerant
Omitted: China
Ceiling cassette
A: 220-240V~/50Hz;
K: 208-230V~/60Hz.
Power supply features 
For R410A refrigerant
Design serial No.
Matching outdoor units: MDS series
Design alternation No.
U: America
E: Other region.
B: Australia
 M CK 032 T P -A M A R
McQuay
Applied region 
Cooling capacity No.(HP)
R: RoHS
 M CC 050 T P -36 R B F A M A R
Type of additional heater
W: hot water coil 
36: 3600W electric heater 
Omitted: no additional heater
Type of connecting pipe
R: right connecting pipe
L: left connecting pipe
Cooling capacity No.(HP)
Ceiling conceal indoor unit
Design serial No.
For R410A refrigerant
McQuay
Applied region Omitted: China, B: Australia, U: America, R
: RoHS, E: Other region.
Power supply features A: 220-240V~/50Hz; K: 208-230V~/60Hz.
Matching outdoor units: MDS series
F: using air filter, X: no air filter
Air return model 
B: rear air return plenum
D: lower air return plenum
C: no air return plenum