Installation manual
©2008 McQuay International 
10
Ceiling concealed Indoor units 
Model 
MCC009TP  MCC011TP  MCC015TP  MCC018TP  MCC020TP 
W  2200  2800  3600  4500  5600 
Cooling 
capacity 
Btu/h  7510  9560  12300  15370  19130 
W  2500  3200  4000  5000  6300 
Heating 
capacity 
Btu/h  8540  10930  13660  17080  21520 
Power 
220-240V~/50Hz 
Sound level dB(A)  31  34  35 
W×D×H(mm)  1054×588×220  1314×610×250 
kg  22  25 
Weight   
lb  49  55 
Power input(W)  47  81  82 
Current(A)  0.21  0.37  0.37 
Fan number  2 
H : m³/h  450  580  800 
Air flow 
H :CFM  265  341  471 
ESP(Pa)  15Pa ,adjustable 
Drain  Φ(mm(in)) 
19.05(3/4”) 
Protection  Anti-freezing, overload 
Gas  expanded copper tube 
Connection
Liquid  expanded copper tube 
LiquidΦ(mm(in)) 
6.35(1/4”) 
GasΦ(mm(in)) 
9.52(3/8”)  12.7(1/2”) 
Model 
MCC028TP  MCC032TP  MCC035TP  MCC045TP  MCC050TP  MCC060TP 
W  7100  8000  9000  11200  12500  14000 
Cooling 
capacity 
Btu/h  24250  27320  30740  38250  42690  47810 
W  8000  9000  10000  12500  14000  16000 
Heating 
capacity 
Btu/h  27320  30740  34150  42690  47810  54640 
Power 
220-240V~/50Hz 
Sound level dB(A)  37  42  43  47  48 
W×D×H(mm)  1314×610×250  1664×610×250  1924×610×250
kg  27  28  39  45 
Weight   
lb  60  62  86  99 
Power input(W)  123  158  210  276  280 
Current(A)  0.56  0.72  0.95  1.25  1.27 
Fan number  2  3  4 
H : m³/h  960  1200  1400  1900  2100 
Air flow 
H :CFM  565  706  824  1118  1236 
ESP(Pa)  15 ,adjustable  30 ,adjustable  50 ,adjustable 
Drain  Φ(mm) 
19.05 
Protection  Anti-freezing, overload 
Gas  expanded copper tube 
Connection
Liquid  expanded copper tube 
LiquidΦ(mm(in)) 
9.52(3/8”) 
GasΦ(mm(in)) 
15.88(5/8”) 
Notes:     
1. Cooling condition: Indoor D/W bulb Temp. 27/19℃,outdoor temperature: D/W bulb Temp.35/24℃. 
2. Heating condition: Indoor D/W bulb Temp. 20/15℃,outdoor temperature: D/W bulb Temp.7/6℃. 
3. Testing power supply: 220V~/50Hz. 