Specifications

38
MVCU-2009 Engineering & Physical Data
General Data - Cooling Only (R22)
MODEL
INDOOR UNIT MCK050A
OUTDOOR UNIT MVCU050A
NOMINAL CAPACITY
Btu/h 49500
W 14508
NOMINAL TOTAL INPUT POWER W 4346
NOMINAL RUNNING CURRENT A 8.3
POWER SOURCE V/Ph/Hz 380 - 415 / 3 / 50
EER W/W 3.34
REFRIGERANT TYPE R22
REFRIGERANT CONTROL (EXPANSION DEVICE) INDOOR CAP. TUBE
INDOOR UNIT
CONTROL
AIR DISCHARGE 4 WAY AUTOMATIC LOUVER (UP & DOWN)
OPERATION WIRELESS OR WIRED MICROCOMPUTER REMOTE CONTROL
AIR FLOW
HIGH l/s / CFM 491 / 1040
MEDIUM l/s / CFM 448 / 950
LOW l/s / CFM 411 / 870
EXTERNAL STATIC PRESSURE (H/M/L) Pa / in.wg. -
SOUND PRESSURE LEVEL (H/M/L) dBA 53 / 52 / 50
UNIT DIMENSION
( ) - WITH PANEL
HEIGHT mm/in 335 (378) / 13.2 (14.9)
WIDTH mm/in 820 (930) / 32.2 (36.6)
DEPTH mm/in 820 (930) / 32.2 (36.6)
PACKING DIMENSION
( ) - PANEL
HEIGHT mm/in 380 (130) / 15.0 (5.1)
WIDTH mm/in 920 (1020) / 36.2 (40.2)
DEPTH mm/in 920 (1000) / 36.2 (39.4)
UNIT WEIGHT (UNIT + PANEL) kg/lb 40 + 4 / 88 + 9
CONDENSATE DRAIN SIZE
mm/in
19 / 3/4
OUTDOOR UNIT
AIR FLOW l/s / CFM 1944 / 4120
SOUND PRESSURE LEVEL dBA 61
UNIT DIMENSION
HEIGHT mm/in 1086 / 42.8
WIDTH mm/in 762 / 30.0
DEPTH mm/in 762 / 30.0
PACKING DIMENSION
HEIGHT
mm/in
1190 / 46.9
WIDTH mm/in 860 / 33.9
DEPTH mm/in 860 / 33.9
UNIT WEIGHT kg/lb 100 / 220
PIPE CONNECTION
TYPE BRAZED VALVE
SIZE
LIQUID mm/in 9.5 / 3/8
GAS mm/in 19 / 3/4
REFRIGERANT CHARGE kg/lb 3.8 / 8.4
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m FROM THE
CENTRE OF THE UNIT.
07_General data.indd 3807_General data.indd 38 4/28/2009 11:20:48 AM4/28/2009 11:20:48 AM