Instruction manual
Figure 25. Installing Filters 
Filter Replacement 
Replace the electrostatic air purifying and deodorizing 
filters every 6 months or sooner if they turn brown. 
Replacement filters can be purchased from your sales 
representative or distributor. 
Use the new filter immediately once it has been 
removed from the package. 
Auto Random Re-start Function 
If there is a power loss to the building, the units will 
randomly restart when the power is restored. Control 
will restart at the last setting regardless of how long the 
power was off. 
Low Ambient Kit 
With this option, the unit can cool down to 32ºF outdoor 
temperature. (Standard units only cool down to 66ºF). To 
install, wire the Fan Speed Control Module (FSCM) in the 
outdoor unit per wiring diagram supplied with the kit. Attach 
the Outdoor Coil Sensor to the return bend as shown in 
Figure 26. Wrap sensor and return bend with insulating 
tape to promote accurate sensing of the refrigerant 
temperature. Refer also to the instructions supplied with the 
kit. 
Figure 26 Low Ambient Location 
Minimum and Maximum Operating 
Temperature 
Cooling 
Temperature  Ts ºF  Th ºF 
Minimum Indoor  67  57 
Maximum Indoor  80  67 
Minimum Outdoor  *66  57 
Maximum Outdoor  115  75 
Heating (Heat Pump Only) 
Temperature  Ts ºF  Th ºF 
Minimum Indoor  50  - 
Maximum Indoor  80  - 
Minimum Outdoor  16  16 
Maximum Outdoor  75  65 
Ts = Dry Bulb Temperature, Th = Wet Bulb Temperature 
* 32ºF with optional Low Ambient Kit 
WARNING 
! 
Disconnect the main power supply before opening 
the return air grille. 
DO NOT restore power until the grille is closed. 
IM-5WMF(SEER13)-0706 
Page 23 