Catalog Horizontal Ducted Condensing Unit Models: M5HDC020AR M5HDC025AR M5HDC-2010
M5HDC-2010 Table of Contents Table of Contents Nomenclature......................................................................................................................2 Indoor Unit......................................................................................................................2 Outdoor Unit...................................................................................................................3 Product Line-Up........................................................
Nomenclature M5HDC-2010 Nomenclature Indoor M 5 CC 020 Brand M : McQuay Refrigerant “ ” 4 5 : Omitted if R22 : R407C : R410A Model Name CC : Ceiling Concealed Capacity Index 020 : 20,000 Btu/h Chassis C : C series Model Type “ ” R 2 : Omitted if cooling only : Heatpump C R
Nomenclature M5HDC-2010 Outdoor M 5 HDC 020 A R Brand M : McQuay Refrigerant “ ” 4 5 : Omitted if R22 : R407C : R410A Model Name HDC : Horizontal Ducted Condensing Unit Capacity Index 020 : 20,000 Btu/h Chassis A : A series Model Type “ ” R : Omitted if cooling only : Heatpump 3
Nomenclature M5HDC-2010 Product Line-Up Indoor Unit M5CC-CR 4 CE EPS Drain Pan Others Air Filter Marking Air Purification Refrigerant Control Bare Fin Handset SLM 3 AFBA AFAA PCB Heat 020CR Pump 025CR L2 M5CC-CR Nomenclature Classification X X X X X X X X X X X X
Hydrophilic Coated Rotary CE Heat Pump Cap Tube M5HDC-AR 020AR AFBA X X X X 025AR AFAA X X X X Nomenclature Others Marking Safety Devices Compressor Fin Refrigerant Control M5HDC-2010 Product Line-Up Outdoor Unit M5HDC-AR Classification 5
Features M5HDC-2010 Features Adequate External Static Pressure The external static pressure is specially designed to blend in most of the interior design and yet to ensure a sufficient heat transfer capability. Aluminium Slit Fin The unique slit fin on the heat exchanger greatly increases the heat transfer efficiency and thus boosts up the unit capacity. Short Piping Reduce installation cost, improved reliability efficiency compared to roof mounted units.
Application Information M5HDC-2010 Application Information Operating Range Ensure the operating temperature is in allowable range. Heatpump Cooling Heating Outdoor temp. (°CDB) 46 35 STD 19 Outdoor temp. (°CWB) 18 6 STD -9 24 15 Indoor temp. (°CWB) 15 21 27 Indoor temp. (°CDB) Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure.
Application Information M5HDC-2010 Refrigerant Circuit Diagram Model: M5CC020CR – M5HDC020AR M5CC025CR – M5HDC025AR 70034 095378 8
Application Information M5HDC-2010 Controller SLM 8 10 9 4 SENSOR ON/OFF AUTO 2 TEMP HIGH MED TIMER HEAT MODE 3 SWING ON/OFF TEMP 7 FAN LOW 5 DRY 1 FAN 2 COOL FAN 4 1 SLEEP 6 6 SWING SLEEP TIMER MODE 3 5 7 Operation Guide 1. “ON/OFF” switch • Press to start the air conditioner unit. • Press again to stop the unit. 2. Temperature setting • Set the desired room temperature. • Press button to increase or decrease the set temperature.
Application Information M5HDC-2010 Installation Guideline Safety Precautions WARNING • Installation and maintenance should be performed by qualified persons who are familiar with local code and regulation, and experienced with this type of appliance. • All field wiring must be installed in accordance with the national wiring regulation. • Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
M5HDC-2010 Application Information Caution Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them. Installation of Indoor Unit For installation of indoor unit, please refer to the indoor unit technical manual. Installation of Outdoor Unit The outdoor unit has to be installed as per recommended installation clearance (Diagram A) Make sure that the location is suitable for piping and drainage. Precaution steps as below : i) Use the hanging bracket supplied with the unit.
Application Information M5HDC-2010 Wiring Wiring Electrical Connections • Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations. General Precautions • Ensure that the rated voltage of the unit corresponds to the name plate before carrying out proper wiring according to the wiring diagram. • Provide a power outlet to be used exclusively for each unit.
M5HDC-2010 Application Information Piping Connection To The Units • Align the center of the piping and sufficiently tighten the flare nut with fingers. • Finally, tighten the flare nut with torque wrench until the wrench clicks. • When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench. Pipe Size (mm/in) 6.35 (1/4) Torque (nm) 18 9.53 (3/8) 42 15.
Application Information M5HDC-2010 4) After evacuation, unscrew the spindle (diagram 2) for the gas to run to indoor unit. Diagram 2 • The refrigerant gas has already charged into the outdoor unit. For the piping length of 5m. Additional refrigerant charge after vacuuming is not necessary. • When the piping length is more than 5m, please use the table below (unit in gram).
M5HDC-2010 Application Information Overall Checking • Ensure the following, in particular :1) The unit is mounted solidly and rigid in position. 2) Piping and connections are leak proof after charging. 3) Proper wiring has been done. • Drainage check - pour some water into drain pan. • Test run 1) Conduct a test run after water drainage test and gas leakage test.
Application Information M5HDC-2010 Special Precautions When Dealing with Refrigerant R410A Unit (1) What is new refrigerant R410A? R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.
M5HDC-2010 Application Information (5) Handling and installation guidelines Like R22 system, the handling and installation of R410A system are closely similar. All precautionary measures; such as ensuring no moisture, no dirt or chips in the system, clean brazing using nitrogen, and thorough leak check and vacuuming are equally important requirements. However, due to its hydroscopic POE oil, additional precautions must be taken to ensure optimum and trouble free system operation.
Sound Data M5HDC-2010 Sound Data Sound Pressure Level Ext. Static Model M5CC020CR M5CC025CR Speed 1/1 Octave A-Weighted Sound Pressure (dBA), ref 20µPa (mmAq) 125Hz 6.5 High 42 6.0 Medium 41 3.5 Low 40 5.5 High 42 4.0 Medium 41 3.0 Low 36 250Hz 39 37 36 41 40 35 500Hz 36 34 32 37 36 33 1kHz 34 31 29 34 33 31 2kHz 28 26 23 31 29 26 4kHz 22 20 18 29 28 27 8kHz 17 15 13 23 22 21 Overall Noise A (dBA) Criteria 38 33 36 30 34 27 40 33 39 32 36 30 Microphone position: 1.
M5HDC-2010 Sound Data M5CC020CR NC Curve 70 Sound pressure level (dB, ref 20µPa) 60 50 NC- 5 0 NC- 4 5 40 NC- 4 0 High fan 30 NC- 3 5 Medium fan NC- 3 0 Low fan NC- 2 5 20 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) M5CC025CR NC Curve 70 Sound pressure level (dB, ref 20µPa) 60 50 NC- 5 0 NC- 4 5 40 NC- 4 0 NC- 3 5 High fan 30 NC- 3 0 Medium fan Low fan 20 NC- 2 5 NC- 2 0 10 0 125 250 500 1000 2000 4000 8000 Octave-band frequency (Hz) 19
Engineering and Physical Data M5HDC-2010 Engineering And Physical Data General Data - Heat Pump (R410A) MODEL INDOOR UNIT M5CC020CR M5CC025CR M5HDC020AR M5HDC025AR Btu/h 18300 22300 W 5360 6540 Btu/h 18500 23500 W 5420 6890 OUTDOOR UNIT NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY NOMINAL TOTAL INPUT POWER (COOLING) W 2350 2930 NOMINAL TOTAL INPUT POWER (HEATING) W 2120 2720 NOMINAL RUNNING CURRENT (COOLING) A 10.5 14 NOMINAL RUNNING CURRENT (HEATING) A 9.9 13.
M5HDC-2010 Engineering and Physical Data Components Data (R22) MODEL INDOOR FAN INDOOR FAN MOTOR INDOOR UNIT M5CC020CR M5CC025CR OUTDOOR UNIT M5HDC020AR M5HDC025AR TYPE CENTRIFUGAL CENTRIFUGAL QUANTITY 2 2 MATERIAL GALVANIZED STEEL GALVANIZED STEEL DRIVE DIAMETER mm/in LENGTH mm/in TYPE QUANTITY INDEX OF PROTECTION (IP) TYPE OUTDOOR FAN 202 / 7.
Engineering and Physical Data M5HDC-2010 Safety Devices MODEL M5CC020CR M5CC025CR M5HDC020AR M5HDC025AR N/A N/A kPa / psi N/A N/A kPa / psi N/A N/A N/A N/A INDOOR UNIT OUTDOOR UNIT TYPE HIGH PRESSURE SWITCH OPEN CLOSE SAFETY DEVICE TYPE LOW PRESSURE SWITCH OPEN kPa / psi N/A N/A CLOSE kPa / psi N/A N/A N/A N/A N/A N/A PHASE SEQUENCER DISCHARGE THERMOSTAT SETTING °C / °F 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
Performance Data M5HDC-2010 Performance Data Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SC at those temperatures which are not stated out in the table. Example: Model: M5CC020CR - M5HDC020AR Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Solution: Overall Based on the Performance Table 1. Refer to the Indoor DB column, - 23°C is located between 20°C and 24°C (Thus, Interpolation need to be applied) 2.
Performance Data M5HDC-2010 Calculation Steps Details: 1st Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 24°C DB, 15°C WB Outdoor Condition: 35°C DB 24 15 16 17 Outdoor DB, ˚C 35 TC (kW) SC (kW) ....................... x1 3.363 3.431 ..... Indoor WB ˚C ..... Indoor DB ˚C y1 2.381 2.288 Total capacity, TC ⇒ x1 = 3.295kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 35°C Outdoor WB)* Sensible capacity, SC Extrapolation Method: ⇒ 17º C – 15º C 2.
M5HDC-2010 Performance Data 2 nd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 35°C DB 20 23 24 15 15 15 ........................ .... Outdoor DB,˚C 35 TC (kW) SC (kW) Indoor WB ˚C .... Indoor DB ˚C 3.295 x3 3.295 1.510 y3 2.474 Total capacity, TC ⇒ x3 = 3.295kW (Same as Total capacity at 20°C Indoor DB / 15°C Indoor WB & 35°C Outdoor WB)* Sensible capacity, SC Interpolation Method: 24º C – 20º C 2.474kW – 1.
Performance Data M5HDC-2010 3 rd Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB 2.233 x y Total capacity, TC Interpolation Method: 40º C – 35º C 2.995kW – 3.295kW ⇒ = 40º C – 37ºC 2.995kW – x ⇒ x = 3.175kW Sensible capacity, SC Interpolation Method: 40º C – 35º C 1.917kW – 2.233kW ⇒ = 40º C – 37º C 1.917kW – y ⇒ y = 2.107kW 26 .... 3.295 .... ............. .... 15 .... 23 ....
M5HDC-2010 Performance Data Performance Table Heatpump (R410A) Model: M5CC020CR - M5HDC020CR Cooling Mode Outdoor DB°C 20 ID DB°C ID WB°C 20 24 28 30 25 30 35 40 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) 15 6.384 4.286 6.049 3.950 5.763 3.665 5.477 3.379 16 6.485 3.986 6.152 3.707 5.844 3.453 5.536 3.199 16 6.485 5.185 6.152 4.906 5.844 4.652 5.536 17 6.591 4.885 6.260 4.662 5.929 4.440 18 6.674 4.562 6.329 4.380 5.985 19 6.
Performance Data M5HDC-2010 Model: M5CC025CR - M5HDC025AR Cooling Mode Outdoor DB°C 20 ID DB°C ID WB°C 20 24 28 30 25 30 35 40 46 TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) 15 6.379 4.076 5.976 3.673 5.606 3.303 5.235 2.933 4.865 2.562 4.420 SC(kW) 2.118 16 6.656 3.828 6.268 3.467 5.897 3.122 5.525 2.777 5.153 2.431 4.707 2.017 16 6.656 5.144 6.268 4.782 5.897 4.437 5.525 4.092 5.153 3.747 4.707 3.333 17 6.
M5HDC-2010 Outline and Dimension Outline and Dimension Indoor Unit Model: M5CC020/ 025CR Note: Dimension in mm Model M5CC020CR M5CC025CR A 1041 1176 B 225 225 C 1002 1137 D 962 1097 E 261 261 F 411 411 G 351 351 H 1065 1200 29
Outline and Dimension M5HDC-2010 Outdoor Unit Model: M5HDC020/ 025AR Note: Dimension in mm 30
M5HDC-2010 Electrical Data Electrical Data Electrical Data - Heatpump (R410A) MODEL INDOOR UNIT OUTDOOR UNIT INSULATION GRADE POWER SOURCE INDOOR MOTOR V/Ph/Hz CLASS E CLASS E 220 240/1/50 220 - 240/1/50 RATED INPUT POWER W 135 152 A 0.60 0.67 MOTOR OUTPUT W 80 100 INSULATION GRADE 4 4 CLASS F CLASS F V/Ph/Hz 220-240/1/50 220-240/1/50 RATED INPUT POWER W 409.7 383.4 RATED RUNNING CURRENT A 1.87 1.
Wiring Diagram M5HDC-2010 Wiring Diagram Heat Pump Indoor Unit Outdoor Unit Model: M5CC020CR Model: M5HDC020AR M5CC025CR M5HDC025AR 70034 095382 32
M5HDC-2010 Service and Maintenance Service and Maintenance Caution Disconnect From Main Supply Before Servicing The Air Conditioner The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedure Recommended Schedule Indoor Air Filter 1.
Service and Maintenance M5HDC-2010 Pre Start Up Maintenance (After Extended Shut Down) - Inspect thoroughly and clean indoor and outdoor units. - Clean or replace air filters. - Clean condensate drain line. - Clean clogged indoor and outdoor coils. - Check fan imbalance before operation. - Tighten all wiring connections and panels. - Check for refrigerant leakage. Most of the parts are accessible by removal of bottom & side panel.
M5HDC-2010 Troubleshooting Troubleshooting Error Code Heatpump Model (Universal Board) Error Code at 7 Segment Display Blink E1 Blink E2 Blink E3 Blink E4 Blink E5 Blink E6 Blink Heat LED Operation / Faulty Indication Room sensor contact loose / short Indoor coil sensor contact loose Outdoor coil sensor contact loose Compressor overload / Indoor coil sensor short / Outdoor coil sensor short Gas leak N/A Outdoor defrost (for Heatpump ony) Fault Condition When any air-conditioner malfunction is noted, imm
Troubleshooting M5HDC-2010 Diagnostic Guidelines By means of pressure reading: Probable cause Too high A little high Normal Circuit A little low Data Too low Pressure High side Low side 1. 2. 3. 4. Overcharged with refrigerant. Non-condensable gases in refrigerant circuit (e.g. air) Obstructed air-intake / discharge. Hot air short circuiting in outdoor unit. High side Low side 1. Poor compression / no compression (compressor defective) 2. Reversing valve leaking. High side Low side 1. 2.
M5HDC-2010 Troubleshooting By means of diagnostic flow chart: The following chart are efficient checking procedures for troubleshooting when these fan coil units, are coupled with the condensing units using standard wiring. For dual circuited models, perform the procedures for each circuit.
Troubleshooting M5HDC-2010 Insufficient Cooling Insufficient Cooling Compressor Cycling Cycling On Dual Pressure Switch Running Overcurrent Relay For Compressor Discharge Gas Thermostat or Internal Thermostat Tripping Tripping Tripping High Discharge Pressure or Low Suction Pressure ........... See "High Discharge Pressure" or Clogged Capillary or Pressure Switch ............... "Low Suction Pressure" Repair Clogging and Replace The Switch If Required Switch Faulty ...........
Troubleshooting M5HDC-2010 High Suction Pressure High Suction Pressure Low Evaporator Air Inlet Temperature Defective Compressor Valve ................. Reduce The Fresh Air Intake ................ Reinforce The Duct Insulation .......... Change Or Repair The Compressor Overcharged Refrigerant ......................
Exploded View and Part List M5HDC-2010 Exploded View and Part List Indoor Unit Model: M5CC020/ 025CR No 1 2 3 4 5 6 Description Cabinet M5CC020CR M5CC025CR Fan Deck M5CC020CR M5CC025CR Assy. Coil M5CC020C M5CC025CR Primary Drain Pan M5CC020CR M5CC025CR Secondary Drain Pan M5CC020C M5CC025C Hanger Part No R01013034005 R01013032362 R50014035082 R50014032629 R50024079268 R50024079271 R50063033908 R50063032369 R50019009407 R50017009420 R01014032372 No Description 7 Parts not in diagram Assy.
Exploded View and Part List M5HDC-2010 Outdoor Unit Model: M5HDC020AR 70014072757 No Description No Description 1 Assy. Front Panel 12 Assy. 4-Way Valve 2 Assy. Drain Pan 13 Tube (Comp. Suct. To Acc. Out) 3 Assy. Base Panel 14 Blower 4 Assy. Coil 15 Fan Motor 5 Compressor Jacket 16 Bracket, Fan Motor 6 Hanging Bracket 17 Top Panel 7 Back Panel 18 Duct, Flange 8 Compressor 19 Service Panel 9 Assy. Flare Valve, 1/2" 20 Terminal Box 10 Assy.
Exploded View and Part List M5HDC-2010 Outdoor Unit Model: M5HDC025AR 70014072758 No Description No Description 1 Assy. Front Panel 12 Assy. 4-Way Valve 2 Assy. Drain Pan 13 Tube (Comp. Suct. To Acc. Out) 3 Assy. Base Panel 14 Blower 4 Assy. Coil 15 Fan Motor 5 Compressor Jacket 16 Bracket, Fan Motor 6 Hanging Bracket 17 Top Panel 7 Back Panel 18 Duct, Flange 8 Compressor 19 Service Panel 9 Assy. Flare Valve, 5/8" 20 Terminal Box 10 Assy.
Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com. © 2010 McQuay International www.mcquay.