Specifications
Model : M5ACV 210CR - Heating
69
WATER AVAIL. PUMP PUMP
HEAT POWER RUNNING  HEAT POWER RUNNING  HEAT POWER RUNNING  FLOW HEAD  INPUT  INPUT 
CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP
kW kW A kW kW A kW kW A m3/hr kPa W A
35 46.14 18.00 36.8 46.75 18.01 36.8 54.77 18.12 37.0 10.75 185 1363 2.5
40 45.01 19.54 40.0 45.84 19.55 40.0 53.59 19.64 40.2 10.50 192 1350 2.4
45 43.87 21.30 43.6 44.88 21.31 43.6 52.51 21.43 43.8 10.30 197 1340 2.4
50 42.07 23.24 47.5 43.16 23.27 47.6 51.19 23.50 48.0 10.12 202 1330 2.4
55 39.76 25.42 52.0 40.93 25.47 52.1 49.62 25.82 52.8 10.01 205 1324 2.4
WATER AVAIL. PUMP PUMP
HEAT POWER RUNNING  HEAT POWER RUNNING  HEAT POWER RUNNING  FLOW HEAD  INPUT  INPUT 
CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP
kW kW A kW kW A kW kW A m3/hr kPa W A
35 59.69 18.30 37.4 64.26 18.48 37.8 67.08 18.72 38.3 10.75 185 1363 2.5
40 58.48 19.79 40.4 62.73 19.93 40.8 65.83 20.12 41.1 10.50 192 1350 2.4
45 57.44 21.59 44.1 61.55 21.80 44.6 64.84 21.93 44.8 10.30 197 1340 2.4
50 56.40 23.76 48.6 60.48 23.87 48.8 64.22 24.06 49.2 10.12 202 1330 2.4
55 55.26 26.12 53.4 59.82 26.37 53.9 63.71 26.64 54.5 10.01 205 1324 2.4
WATER AVAIL. PUMP PUMP
HEAT POWER RUNNING  HEAT POWER RUNNING  FLOW HEAD  INPUT  INPUT 
CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP
kW kW A kW kW A m3/hr kPa W A
35 72.36 19.21 39.3 83.37 20.82 42.6 10.75 185 1363 2.5
40 70.88 20.50 41.9 81.98 22.03 45.0 10.50 192 1350 2.4
45 69.72 24.43 49.9 81.04 23.97 49.0 10.30 197 1340 2.4
50 69.72 24.43 49.9 80.82 26.10 53.4 10.12 202 1330 2.4
55 69.00 27.16 55.5 29.14 29.14 59.6 10.01 205 1324 2.4
 LEAVING WATER TEMP (°C
)
 LEAVING WATER TEMP (°C
)
AMBIENT TEMPERATURE ON CONDENSOR (°C)
AMBIENT TEMPERATURE ON CONDENSOR (°C)
AMBIENT TEMPERATURE ON CONDENSOR (°C)
 LEAVING WATER TEMP (°C)
-7 -5 0
4710
15 21
M5ACV210CR
MODEL
M5ACV210CR
MODEL
M5ACV210CR
MODEL