Specifications
Performance Data
Model : M5ACV 030CR / 055CR - Cooling
62
WATER AVAIL. PUMP PUMP
COOL POWER RUNNING  COOL POWER RUNNING  COOL POWER RUNNING  COOL POWER RUNNING  FLOW HEAD  INPUT  INPUT 
CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP
kW kW A kW kW A kW kW A kW kW A
m
3
/hr
kPa W A
49.793.8114.19.693.9714.79.134.6217.18.694.9018.11.26 82 194 0.9
5 10.03 3.84 14.2 9.94 4.01 14.8 9.36 4.67 17.2 8.91 4.95 18.3 1.30 82 196 0.9
610.273.8914.410.174.0414.99.564.7117.49.094.9918.41.32 79 197 0.9
710.473.9114.410.384.0815.19.784.7617.69.325.0518.71.36 76 199 0.9
8 10.96 3.97 14.7 10.84 4.14 15.3 10.14 4.81 17.8 9.61 5.09 18.8 1.39 76 201 0.9
9 11.29 4.01 14.8 11.21 4.18 15.4 10.38 4.86 17.9 9.82 5.14 19.0 1.43 74 203 0.9
10 11.86 4.07 15.0 11.73 4.23 15.6 10.93 4.90 18.1 10.34 5.18 19.1 1.49 73 206 0.9
4 13.09 4.06 8.6 12.76 4.31 9.1 11.30 5.11 10.8 10.56 5.59 11.9 1.58 170 211 0.9
5 15.04 4.18 8.9 14.80 4.43 9.4 13.62 5.24 11.1 12.95 5.72 12.1 1.97 155 231 1.0
6 16.36 4.29 9.1 16.21 4.54 9.6 15.37 5.35 11.3 14.80 5.83 12.4 2.28 140 248 1.1
7 17.99 4.42 9.4 17.85 4.68 9.9 17.01 5.49 11.7 16.40 5.98 12.7 2.52 127 260 1.1
8 18.99 4.50 9.6 18.87 4.76 10.1 18.09 5.56 11.8 17.47 6.05 12.8 2.69 118 269 1.2
9 20.31 4.61 9.8 20.12 4.86 10.3 19.05 5.67 12.0 18.28 6.16 13.1 2.78 112 274 1.2
10 20.99 4.71 10.0 20.75 4.96 10.5 19.44 5.76 12.2 18.56 6.25 13.3 2.80 111 275 1.2
WATER AVAIL. PUMP PUMP
COOL POWER RUNNING  COOL POWER RUNNING  COOL POWER RUNNING  COOL POWER RUNNING  FLOW HEAD  INPUT  INPUT 
CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP
kW kW A kW kW A kW kW A kW kW A
m
3
/hr
kPa W A
48.355.0318.67.985.1419.07.355.2225.96.145.2719.51.26 82 194 0.9
58.565.0918.88.175.1919.27.535.2726.16.295.3119.61.30 82 196 0.9
68.735.1319.08.345.2319.37.695.3126.36.425.3419.81.32 79 197 0.9
78.965.2019.28.565.3019.67.915.3726.66.605.3919.91.36 76 199 0.9
89.225.2319.38.795.3219.78.095.3926.76.755.4220.01.39 76 201 0.9
99.455.2719.58.975.3719.88.335.4326.96.985.4520.11.43 74 203 0.9
10 9.90 5.31 19.6 9.42 5.40 20.0 8.64 5.46 27.1 7.16 5.48 20.3 1.49 73 206 0.9
4 10.11 5.91 12.5 9.71 6.23 13.2 9.20 6.94 14.9 8.56 7.51 15.9 1.58 170 211 0.9
5 12.50 6.04 12.8 12.07 6.37 13.5 11.44 7.08 15.2 10.43 7.66 16.2 1.97 155 231 1.0
6 14.39 6.15 13.1 13.96 6.48 13.7 13.26 7.18 15.5 11.98 7.77 16.5 2.28 140 248 1.1
7 15.95 6.31 13.4 15.46 6.64 14.1 14.65 7.35 15.8 13.12 7.94 16.9 2.52 127 260 1.1
8 17.00 6.37 13.5 16.48 6.70 14.2 15.62 7.40 15.9 13.93 7.99 17.0 2.69 118 269 1.2
9 17.72 6.48 13.8 17.13 6.81 14.5 16.15 7.51 16.2 14.34 8.10 17.2 2.78 112 274 1.2
10 17.94 6.57 13.9 17.30 6.89 14.6 16.27 7.59 16.4 14.41 8.19 17.4 2.80 111 275 1.2
WATER AVAIL. PUMP PUMP
COOL POWER RUNNING  COOL POWER RUNNING  FLOW HEAD  INPUT  INPUT 
CAP. INPUT CURRENT CAP. INPUT CURRENT RATE PRESS. POWER AMP
kW kW A kW kW A
m
3
/hr
kPa W A
45.285.3919.93.785.4120.01.26 82 194 0.9
55.425.4019.93.895.4320.11.30 82 196 0.9
65.555.4220.04.015.4520.11.32 79 197 0.9
75.715.4420.14.135.4720.21.36 76 199 0.9
85.845.4620.24.245.5020.31.39 76 201 0.9
95.985.4720.24.365.5220.41.43 74 203 0.9
10 6.20 5.50 20.3 4.48 5.56 20.5 1.49 73 206 0.9
48.198.3117.68.158.3417.71.58 170 211 0.9
59.488.4618.09.308.4918.01.97 155 231 1.0
6 10.55 8.57 18.2 10.24 8.60 18.3 2.28 140 248 1.1
7 11.36 8.76 18.6 10.98 8.79 18.7 2.52 127 260 1.1
8 11.94 8.80 18.7 11.51 8.83 18.7 2.69 118 269 1.2
9 12.28 8.91 18.9 11.83 8.95 19.0 2.78 112 274 1.2
10 12.38 8.99 19.1 11.95 8.96 19.0 2.80 111 275 1.2
M5ACV055CR
MODEL
M5ACV030CR
MODEL
M5ACV030CR
MODEL
M5ACV030CR
M5ACV055CR
M5ACV055CR
 LEAVING WATER TEMP (°C
)
 LEAVING WATER TEMP (°C
42 46
30 32
AMBIENT TEMPERATURE ON CONDENSOR (°C)
AMBIENT TEMPERATURE ON CONDENSOR (°C)
35 40
 LEAVING WATER TEMP (°C
19 20 25
AMBIENT TEMPERATURE ON CONDENSOR (°C)
28