Operating instructions

IMM ACZ/AGZ-4 ACZ / AGZ-BM 35
Table 23, ACZ BC & AGZ BM Field Wiring, Single Point
Wiring to Standard
Power Block
Wiring to Optional
Non-Fused Disconnect Switch
ACZ
Unit
Size
AGZ
Unit
Size
Volts
Terminal
Amps
Connector Wire
Range
(Copper Wire Only)
Disconnect
Size
Connector Wire
Range
(Copper Wire Only)
208 175 14 GA – 2/0 225 # 4 - 300 kcmil
230 175 14 GA – 2/0 225 # 4 - 300 kcmil
380 175 14 GA – 2/0 150 # 4 - 300 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
030B 026B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
230 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
380 175 14 GA – 2/0 150 # 4 - 300 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
035B 030B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
230 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
380 175 14 GA – 2/0 150 # 4 - 300 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
040B 035B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
230 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
380 175 14 GA – 2/0 150 # 4 - 300 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
045B 040B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
230 380 #4 – 500 kcmil 225 # 4 - 300 kcmil
380 175 14 GA – 2/0 150 # 4 - 300 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
050B 045B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 250 #6 - 350 kcmil
230 380 #4 – 500 kcmil 250 #6 - 350 kcmil
380 175 14 GA – 2/0 150 # 4 - 300 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
055B 050B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
230 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
380 175 14 GA – 2/0 250 #6 - 350 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
060B 055B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
230 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
380 380 #4 – 500 kcmil 250 #6 - 350 kcmil
460 175 14 GA – 2/0 150 # 4 - 300 kcmil
065B 060B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
230 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
380 380 #4 – 500 kcmil 250 #6 - 350 kcmil
460 175 14 GA – 2/0 250 # 4 - 300 kcmil
070B 065B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
208 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
230 380 #4 – 500 kcmil 400 250 kcmil -500 kcmil
380 380 #4 – 500 kcmil 250 #6 - 350 kcmil
460 380 #4 – 500 kcmil 250 # 4 - 300 kcmil
080B 070B
575 175 14 GA – 2/0 150 # 4 - 300 kcmil
All Electrical Data notes are on page 49.