Installation manual
Page 40
Group MMSI Numbers
A radio may be a member of up to 4 MMSI groups (for example, a group MMSI
could be assigned to a fishing fleet).
Setting a group MMSI is similar to the process for setting the individual MMSI.
1. After selecting Profiles – MMSI number,
scroll to Group MMSI and press Select.
Group 1 is displayed first;
Groups 2, 3, and 4 are displayed by scrolling.
2. Press Edit to enter the Group MMSI
number. When entering the MMSI number, the
first ‘0’ cannot be changed (because it
identifies a MMSI as a group number). The
Back Action key changes to Clear as you
enter digits.
3. When the Group MMSI is entered, press
Save. The Edit screen, showing the group
MMSI is then displayed and it is possible to
Edit the number again, or use the Back / Exit
key to return to the standby screen.
Unlike the individual MMSI number, Group MMSIs can be edited and deleted.
Scan Dwell Time
The Scan Dwell Time is the length of time the radio monitors each channel when in
Scan mode.
To set the Scan Dwell Time:
1. In standby screen, press Menu, then scroll
to Profiles and press Select.
2. Scan dwell time is the first option
displayed. Press Select.
3. The Dwell Time is changed using the Scroll
keys. Time increments / decrements are
50ms. Press Save when the desired dwell
time is displayed.
MMSI number
Group MMSI
Select Back
Group MMSI number
Group 1:
Edit Back
Group MMSI number
Group 1:0|
Save Back
Profiles
Select Exit
Profiles
Scan dwell time
Select Back
Scanning [msec]
Set dwell time: 200
Save Back