Specifications

3. WAKE UP PRECONDITIONING
a. All Area Controllers may be programmed for
specific "Wake Up" conditions by the installer.
b. Jumpers can select either the last used or
TUNER input for "Wake Up."
c. Jumpers can select either the last used or a
present VOLUME LEVEL.
REMOTE OPERATION (SENSOR)
The front panel contains an IR sensor for operation
within the room.
An F connector is provided on the rear panel for a
second Main sensor.
Each "Plug In" AREA CONTROLLER has its own F
connector for a remote sensor.
The electrical design of the remote sensor has been
changed (no mechanical change) to indicate four
conditions.
1. Area "ON" - Red LED illuminated.
2. Area MUTE - Red LED flashing off and on at
uniform 1 second rate (.5 ON, .5 OFF).
3. Receiving Transmission - Red LED flashing
rapidly and irregular.
4. Area OFF - Red LED off.
The design of the current source that supplies the
75 ohm cable has been changed so that up to 4 sensors
or keypads can be operated in parallel.
NOTE: R649 sensors must be used. The obsolete
R607 will not work with the CR10.
KEYPADS
A wall mounted (dual electrical box) Keypads will
be an available option. It will contain a sensor and the
status LED defined above. Power will be supplied by
the 75 ohm cable.
EXPANSION OF BASIC CR10 SYSTEM
AC POWER CONTROL
AC power control is provided in a separate unit, the
PC1. Control information from the CR10 is passed on
to the control via a 7 conductor cable. Power input to
the controller is 120VAC at 15 amps. A 3 conductor
14GA line cord with heavy duty plug is provided.
VIDEO EXPANSION
Expansion of the VIDEO and AUDIO capability for
the CR10 system is supplied by the MVS3. It provides
5 more audio inputs switched simultaneously with 5
VIDEO and 5 Super VHS inputs.
HOME CONTROL
The MHC1, HOME CONTROL MODULE provides
switching to control lighting, drapery motors, screen
motors, and other appliances.
MASTER CONTROL
A CONTROLLER INPUT CONNECTOR is provided on
the rear panel for connection of a full featured Mclntosh
CONTROL CENTER (preamp). All the audio input and
data connections are made through this connector.
ADDITIONAL REMOTE CONTROL AREAS
Up to 20 more AREAS can be added to the system.
The NEXT CONTROLLER CONNECTOR on the rear of
CR10 number one can be connected to the CONTROL-
LER INPUT CONNECTOR on CR10 number two. Two
to three in the same fashion and so on for up to six
CR10s. Since each CR10 contains buffer amplifiers for
each input the chain can go on and on. A small
decrease in Signal to Noise Ratio would be the only
penalty.
Issued by Engineering Department:
December 2, 1991
Revised: December 9, 1991
March 16, 1992
March 26, 1993
MclNTOSH LABORATORY INC., 2
CHAMBERS STREET, BINGHAMTON,
NEW
YORK
13903
CR10 Product Preview/Page 4