e. Screw float and float rod (C) into float arm (K)
and hand tighten. Center the float rod in the float
rod guide (not shown) and tighten Torx
®
screw (D)
to 125 in. lbs. (14N•m). Make sure you hold the
float in place while tightening screw (D). Move the
float up and down, making sure there is no binding
and that the float rod is still centered. Install bracket
(P) using screws (N), tighten to 40 in. lbs.
(4.5 N•m).
a. Clean the gasket surface on head casting (B) and the body casting. Using a new gasket (furnished)
mount the head mechanism to the body casting. Tighten the eight (8) bolts to 18 ft. lbs. (24N•m).
Reattach conduit connectors and connect wires to the proper terminals. Turn on electrical power to the
boiler.
STEP 4 - Assembling the Head to the Body and Test for Proper Operation
b. Run the unit through several cycles of operation, noting the operating points. On the snap
switch controls it may be necessary to readjust the switches. If this is necessary follow the
enclosed instructions. (See attached for reference only, MM-235).
d. Make sure the tapped hole on float arm (K) is
facing the correct way, so the float and float
rod (C) can be screwed into it when bellows
assembly is assembled on the head casting.
Place gasket (M) on head casting (B). Center the
gasket and place the bellows assembly (F) and
the switch housing (A) on head casting (B). Insert
and tighten the six (6) Torx
®
screws (E) to 125 in.
lbs. (14N•m). Make sure that two (2) of the screws
capture the switch bracket (R).
D
H
G
J
K
E
D
R
A
B
P
J
C
H
N
L
F
K
M
c. Take the new bellows assembly (F) and disassemble
it noting the order of parts. Put sealing washer (J)
on top of float arm (K) and insert into inside of
bellows (F). Place gasket (L) over bellows (F).
Insert this assembly into switch housing (A) and
bracket (H). If the screw (D) was an Allen
®
screw,
the spacer washer (G) will have to be put in the top
hole of bracket (H). Take Torx
®
screw (D)
(furnished) and insert it into hole on top of bracket
(H) and spacer washer (G) (if needed) and screw
into float arm (K). Hand tighten only.
Step 3 - Changing the Bellows for Snap Switch Units cont’d)
b. NOTE: On units that have Allen
®
head screws they
will be replaced with Torx
®
screws (furnished).
ITT
8200 N. Austin Ave.
Morton Grove, IL 60053
tel: 847-966-3700
fax: 847-966-9052
www.mcdonnellmiller.com
©2007 ITT Corporation
Printed in U.S.A. 5-07 246765
McDonnell & Miller