User manual

POWER/ELECTRICAL CONNECTION Operating guide for Alarm Receiver Decrypta 4 11|52
MCDI SECURITY PRODUCTS INC. 7055 Jean-Bourdon Montréal Québec Canada +514.481.1067 www.mcdi.com ed@mcdi.com
Best practice in making a ground connection from Ed
are to insure a non resistive connection to a known and tested ground in
a well built electrical installation or connect the ground lug of PC to a metallic water pipe going to earth or to a rod deeply
planted to earth.
Connection to ground should be verified regularly. If connection to ground is not well established and maintained, electrical
surge protection of phone lines is absent.
Alternative for ground posts directly on Ed are: pin 1 or relay connector J10 or mounting hols at the far right (when look at board
top component side). Consult MCDI prior to using mounting holes as ground post.
WARNINGS
-Ed
does not supervise battery other than provide an approximate measure of tension.
-Verify electrical set-up regularly.
-Always use properly mounted and approved cables to connect Ed.
-Do not use an over charger battery or a battery dispensing more than 14VDC.
-Consult a qualified Electrician prior to connecting Ed
If you are using a battery, a battery charger and/or equipment not
provided by MCDI Security Products Inc.
-Damages resulting from power surges of any kind are specifically excluded from Ed
warranty.
USING ON-BOARD RELAY
Ed
is equipped with a relay to trigger an external device such as strobe light, dialer or siren upon reception of an alarm signal.
Terminal posts are located on Jumper J10.
Pin out:
Pin 1: ground
Pin 2: normally closed
Pin 3: common
Pin 4: normally open
Maximum rating : UL/CSA rating : Nominal 30V DC / 1A 125V AC 0.5 A . Applying more than 110V DC or 125V AC will damage
the Ed.
It is preferable to consult an electrician or MCDI prior to connect any equipment to Ed relay post.