Service manual

Fixes
Table 2 lists issues that have been xed in this release.
Table 2 Fixes
in th is release
Description
Affected mod els
After upgrad
inganEdgeSwitch2/32,yellowtriangles
are shown on HAFM for all ports that are inactive but
have optics in them.
Edge Switch 2
/32 (Sphereon 3232)
Trace route port IDs have incorrect ll byte. Zero ll byte
shouldbeLSBnotMSBaccordingtoGS-5andSW-4
Firmware family
Event 507 occurs after hot insert of multiple UPM cards.
This has only been encountered when cards are inserted
on one-minute intervals.
Director 2/140 (Intrepid 6140 Director)
Firmware fault 57 20 causes servers to go ofine. Director 2/140 (Intrepid 6140 Director )
Edge Switch 2/12 and Edge Switch 2/24 do not send
R_RDY for frames with invalid D_DID of 0 during IPL. This
causes ports to log out and log back in during IPL after
upgrading code from 7.1 to 8.1.
Edge Switch 2 /12 (Sphereon 4300)
Edge Switch 2/24 (Sphereon 4500)
Loss-of-signal o r loss-of-synchronization counters always
show zero.
Edge Switch 2/24 (Edge Switch 4500)
Sphereon 4700
516 e v e n t
s are logged after upgrading to 8.0.1.
Equipment check occurs when the threshold is exceeded
on the u nused ports.
Sphereon 4400
Logging anomalies are in a failure on port 2F. Firmware family
Frames a
re not routed to ISL when ITWs are being
detect
ed on another F-por t, causing ABTS.
Sphereo
n4700
Hard zoning and reroute programming delays occur due
to large number of devices and DID’s in the fabric. The
delay occurs when taking the core director ofine/online.
Firmware family
Trace route will not work with a standard compliant
switch (QLogic) when using port IDs; however, WWNs
will work. Trace route port IDs have incorrect ll byte.
Zero ll byte should be LSB not MSB according to GS-5
and SW-4 standards.
Firmware family
In a VTC/VTS environment, multip le directors become
inoperable; this condition requires power on reset.
Edge Switch 2/32 (Sphereon 3232)
IfFCZisdisabledandaCHPIDWWNisalreadyin
the exempt host list, when a user enables FCZ, only the
rstlogicalpathforthatCHPIDissetasacontrolhost
path. All other logical paths for that CHPID remain set
as partitioned host paths. These path s will not be set
correctly unless the host CHPID is forced to log in into
the switch aga in.
Firmware family
An SDC interface physical identierforneighbornode
(mainframe channel) is being returned incorrectly to an
MVS host in-band request.
D i re c t o r 2 / 14 0 ( I n t r e p i d 6140 D i re c t o r )
Edge Switch 2/16 (Sphereon 3216)
Edge Switch 2/12 (Sphereon 4300)
Boxed CUPo ccurs after rmware upgrade Firmware family
Intermittent 17020 fault occurs when migrating from 7x
rmware.
Director 2/140 (Intrepid 6140 Director)