Service manual
Using HAFM Basic
To determine the current version using HAFM Basic (firmware 08.xx.xx or later):
1. Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
The Fabric View appears.
2. Click Detai
ls for the Edge Switch or Director. The Product > Hardware view appears.
The firmw are
version appears in this view.
Using Embedded Web Ser ver
To determine the current version using the Embedded Web Server (firmware 07.xx.xx or earlier):
1. Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
2. Select View from the navigation panel on the left.
3. Select the Unit Properties tab.
The firmware version appears in the unit properties tab.
Using the CLI
To deter
mine the current version using the CLI:
1. Telnet
to the Edge Switch or Director using the IP address of the switch.
2. Enter the show system command.
The firmware version appears in the resulting system information display.
Supersedes history
This version supersedes firmware 8.02.00.
Effective date
September 2006
Director and Edge Switch release notes
17