Service manual

When downgrading to a release earlier than 07.00.00, any mod ications to the port RX
BB_Credit settings using the new enhanced port conguration capability must be changed back
to a conguration supported by older rmware. This enables the conguration to comply with the
previous release’s conguration database. Firmware 07.xx.xx services verify compatibility and
prevent downloads until the conguration conict is resolved.
Downgrading directly to a release prior to 08.xx.xx from 09.00.00 is not allowe d. To downgrade
to a release prior to 08.xx.xx, you must rst downgrade to 08.02.00.
Upgrades and downgrades are suppor ted only from one major release to the next, such as from
08.xx.xxto09.00.00.IfHAFMBasicisusedforupgradesanddowngrades,andthisruleisnot
followed, errors occur and there may be a disruption to attached devices.
Downgrading to release 06.xx.xx with the Preferred Path feature congured can cause loss of
this function. HP recommends that Preferred Path be disabled before downgrading. To do this,
deselect the Enable Preferred Path check box in the Congure Preferred Paths dialog box.
The Director 2/140 and Edge Switch 2 /24 cannot be downgraded to a version earlier than
04.01.00. The Edge Switch 2/12 cannot be downgraded to a version earlier than 05.05.00.
Second-generation Edge Switch 2/12 and Edge Switch 2/24 switches cannot be downgraded
to a version earlier than 06.02.00.
If a Director 2/140 in a multiswitch fabric is downgraded to a version earlier than 06.02.00, ISLs
can become segmented if there are any other switches in the fabric operating with a rmware
version earlier than 06.01.00. To prevent this situa tion, downgrade all Director 2/140s in the
fabric to 06.01.00 before downgrading any products in the fabric to 05.xx.xx. This problem only
exists with Director 2/140s in the fabric. HAFM displays a warning message if a downgrade
from 06.02.00 is at tempted, but you can c ontinue with the downgrade if desired.
NOTE:
A warning message appears when downgrading any model from 06.02.00, but only applies to
downgrade op erations for the Director 2/140.
For procedures to download rmwar e to the Edge Switch or Director using the HAFM Element Manager
interface or HAFM Basic interface, see the following:
The Edge Switch or Director installation and service manual—Provides complete pr ocedures for
obtaining rmware from the H P web site and downloading rmw are to the Edge S witch or
Director using HAFM.
The Edge Switch or Director Element Manager online help and user gu ide—Provide instructions
for downloading rmware to the Edge Switch or Director using the HA FM interface.
HAFM Basic user guide and online help—Provides procedures for downloading rmware to
theEdgeSwitchorDirector.
HAFM upgrade required for rmware 09.00.00
Consider the following HAFM requirements for rmware 09.00.00:
To upgrade to rmware 09.00.00, you must rstupgradetheHAFMsoftwareto07.02.00-9
if you are using the Notebook HAFM Server to manage the Director or Edge Switch. The
HAFM software is contained on the HP StorageWorks HA-Fabric Manager Documentation and
Software CD (Part Number 516-000024-710). This HAFM is available on the HP web site
h
ttp://h18006.www1.hp.com/storage/saninfrastructure/index.html.
Director and Edge Switch release notes
13