Service manual

Firmware installation
This section includes rmware installation information.
Prerequisites for installing and using rmware 09.00.00
Consider the following prerequisites for rmware 09.00.00:
If you are using HAFM, rmware 09.00.00 requires HAFM 07.01.00 or later. This minimum
version lets you manage Edge Switches and Directors running 09.00.00 rmwar e. Howe ver, to
use all the new features and enhancements for rmware version 05.xx.xx and later, upgrade
HAFM to 08.09.01, which only runs on the HAFM Appliance (see Table 3).
Check with HP Customer Support for the latest shipping version of HAFM. HAFM s hould be at the
minimum level before installing the new rmware.
If you are using HAFM to upgrade rmware, an Edge Switch 2/24 must be managed with HAFM
08.08.00 or higher before upgrading to rmware 08.xx.xx or later. If you upgrade to rmware
08.xx.xx or later using an HAFM release earlier than 08.08.00, the rmware upgrade may fail.
Firmware 08.01.00 introduced slightly more processor utiliza tion, which can cause the download
to occasionally exceed HAFM’s timeout. As an alternative to HAFM, use the switch’s HAFM Basic
interface (formerly EWS) to upgrade rmware.
Firmware upgrades or downgrades should not be per formed using HAFM Basic using Internet
Explorer 5.00.3315.1000x. If this operation is per formed, the download operation may not
complete and may eventually time out, leaving the switch with the previous version of rmware.
NOTE:
HAFM is not required for operating hardware products using the rmware.
All Edge Switches and Directors in the same fabric should have the same rmware level installed.
Although products can coexist in a fabric running different levels of rmware, all products must
be at the same major functional release level.
Upgrading from an earlier version of rmware
Upgrading to rmware 09.00.00 is nondisruptive to attached devices. The Director or Edge Switch is
not required to be off line before performing an upgrade operation. Limitations to upgrades are clearly
identied if there are any limitations to performing the operation.
Consider the following when upgrading rmware:
Before upgrading rmware, HP recommends that you back up the Director or Edge Switch
conguration. See the HP StorageWorks Director Element M anager user guide for more
information. HAFM Basic also provides an o ption to print or save product conguration to a le.
See the HAFM Basic user guide for more information.
All products must be running rmware 08.xx.xx or later before upgrading to 09.00.00. If a
switch is operating with a rmware level earlier than 08.xx.xx, you must upgrade to 08.02.00
before installing 09.00.00
Upgrades and downgrades a re supported only within a major release, such as 08.xx.xx to
08.xx.xx, or from one major release to the next, such as from 07.01.03 to 08.02.00, or 08. 02.00
to 09.00.00. If HAFM Basic is used for upgrades and downgrades, and this rule is not followe d,
errors occur and there may be a disruption to at tached devices.
10