User manual
1
1-20
McDATA Sphereon™ 4500 Fabric Switch Product Manager User Manual
Product Manager Overview
Enable Web Server
Select this option place a check mark in the check box to enable
the SANpilot Interface on the switch. Select the option again to
remove the check mark and disable the SANpilot Interface. When
disabled, users at remote workstations cannot access the
interface.
Enable Telnet
Select this option place a check mark in the check box to enable
the telnet access to the switch. Select the option again to remove
the check mark and disable the telnet access. When disabled,
users at remote workstations cannot use telnet to access the
switch.
Logs Menu
Place the cursor over the Logs menu to display a menu that lists the
following options. For detailed information on using these dialog
boxes, refer to Chapter 4, Using Logs.
Audit Log
This log provides a record of all configuration changes made on
the switch. Each entry displays the date and time of the change, a
description of the change, the source of the change (such as the
EFC Server or SNMP management station), and an identifier for
the source, such as the IP address of the EFC Server or SNMP
management station.
Event Log
Select this option to display the switch event log. This log
provides a record of significant events that have occurred on the
switch, such as hardware failures, degraded operation, and port
problems. Each entry includes the date and time of the event, a
reason code for the event, the severity level, a brief description,
and up to 32 bytes of supplementary event data. Refer to the
McDATA Sphereon 4500 Fabric Switch Installation and Service
Manual (620-000159) for more information.
Hardware Log
This log displays information on FRUs inserted and removed
from the switch. Each log entry includes the name of the FRU
inserted or removed, the slot position relative to identical FRUs
installed, whether the FRU was inserted or removed, the FRU
part number and serial number, and the date and time the FRU
was inserted or removed.