Specifications
Firmware Summary
B-11
Firmware Summary
FICON management
style support
User-selectable option on a per
product basis. Setting is stored
on the product.
User-selectable option on a per
user (different for each login ID)
or per product basis. Setting is
stored on the management
server, not the product. Setting is
backed up by the server backup
process.
FICON management style not
supported through the
SANvergence Manager
application.
LED status indicators For director CTP and SBAR card
LEDs: Green LED indicates
active or standby. Amber LED
indicates failed or beaconing.
For director FPM, UPM, or XPM
card LEDs: Amber LED indicates
failed or beaconing.
For switches: Green PWR LED
indicates operational. Amber
ERR LED indicates failed or
beaconing.
For CTP, SWM, or LIM card
State LED (bicolor LED): Green
indicates online. Amber indicates
failed, degraded, or beaconing.
For CTP card Role LED (bicolor
LED): Green indicates active or
standby. Amber indicates failed.
Green SYS LED indicates SAN
router operational.
For Eclipse 1620 SAN Router,
green PS1 and PS2 LEDs
indicate power supplies
operational.
Access to simple name
server (SNS) database
User can only view local SNS
database through the EFCM
application and CLI interface.
User can view local SNS
database through the EFCM
application and CLI interface.
User can view global SNS
databases only through the CLI
interface.
User can view local and global
SNS databases through the
SANvergence Manager
application. User can view only
local SNS database through the
Element Manager application.
CLI interface only shows SNS
database for direct-attached
devices.
Date and time
synchronization
Periodic and user-initiated Sync
Now date
and time synchronization
between EFCM application and
product supported.
Periodic date and time
synchronization between EFCM
application and product not
supported. Application supports
user-initiated Sync Now function
for the Intrepid 10000 Director.
Periodic date and time
synchronization between
SANvergence Manager
application and product not
supported.
Hard zoning restriction
(fabric size and port
type)
No zoning restriction based on
fabric size and port type.
When a paddle pair exceeds
seven E_Port connections and
the fabric node count exceeds
800 devices, hard zoning is
disabled for that paddle pair.
No zoning restriction based on
fabric size and port type.
Table B-3 E/OSc versus E/OSn and E/OSi - Management-Related Differences (Continued)
Feature E/OSc 8.0 E/OSn 6.0 E/OSi 4.6