User manual

A
A-12
E/OS Command Line Interface User Manual
Action Reduce the number of members in one or more zones and re-submit
the command.
Message Error 077: Not Allowed While Port Is Failed
Description The port selected is in a failed or inactive state, or is in need of
service.
Action Consult the installation/service manual for appropriate action.
Message Error 078: System Error Light On
Description This unit is not able to beacon because the system error light is on.
Action You must clear the system error light before unit beaconing may be
enabled. Consult the installation/service manual for appropriate
action.
Message Error 079: FRU Failed
Description The specified FRU has failed.
Action Consult the installation/service manual for appropriate action.
Message Error 081: Default Zone Enabled
Description The request cannot be completed because the default zone is enabled.
Action Disable the default zone and re-submit the command.
Message Error 082: Invalid Interop Mode
Description The value entered for the interoperability mode is not valid.
Action The interoperability mode for the director or switch must be mcdata
(McDATA Fabric 1.0) or open (Open Fabric 1.0). Make the
appropriate changes and re-submit the command.