User manual
2
CLI Commands
2-223
show
Command Example Show port opticEDD
Output The port optic diagnostic data is displayed as a table that includes the
following properties.
Output Example The show.port.opticEDD command output appears as follows:
Port Xvr Temp 3.3 VoltCurrent TX Power RX Power1.8 Volt5.0 Volt
---- --- ----- -------- ------- --------- ----------------- -------
0 UNK UnknownUnknownUnknownUnknown Unknown UnknownUnknown
1 UNK UnknownUnknownUnknownUnknown Unknown UnknownUnknown
2 UNK UnknownUnknownUnknownUnknown Unknown UnknownUnknown
3 UNK UnknownUnknownUnknownUnknown Unknown UnknownUnknown
4 XFP 36.1053.2565.324 602.100 289.3001.7794.998
show.port.opticHealth
Syntax opticHealth
Purpose This command shows the overall optic health for all ports that
support Enhanced Digital Diagnostics (EDD).
NOTE: At unit startup, the health of the optics will be read at roughly one
optic per second, and once it reaches the last port, it start from the beginning
and update any changes.
Parameters This command has no parameters.
Port The port number.
Xcvr The transceiver type.
Temp The optic temperature in celsius.
3.3 Voltage The 3.3 voltage in volts.
Current The current in mA.
TX Pwr The transceiver power in uW.
RX Pwr The receiver power in uW.
1.8 Voltage The 1.8 voltage in volts.
5.0 Voltage The 5.0 voltage in volts.