User manual
2
2-222
E/OS Command Line Interface User Manual
show
Output This command displays the following optic data:
Output Example The output from the show.port.opticData command appears as follows:
Port Number: 5
Overall Health: Alarm
Transceiver: SFP
Type Value Low Warning High Warning Low Alarm High Alarm
----------- ------- ----------- ------------ --------- ----------
Temperature 134.600 -40.000 100.000 -45.000 105.000
3.3 Voltage 3.290 3.000 3.600 2.900 3.700
Current 7.460 4.600 14.800 3.100 20.000
TX Power 400.000 112.000 398.000 89.000 501.000
RX Power 17.000 13.000 1000.000 4.000 1259.000
1.8 Voltage N/A N/A N/A N/A N/A
5.0 Voltage N/A N/A N/A N/A N/A
Temperature High Alarm
TX Power High Warning
show.port.opticEDD
Syntax OpticEDD
Purpose This command displays Enhanced Digital Diagnostics (EDD)
information for all ports. This information is in HEX format. If there
is no port connected then “Unk” is displayed. For ports that are
connected and does not support predictive optics monitoring feature
will display “Unknown”.
Parameters This command has no parameters.
Type The measurement type. Temperature is in celsius,
voltage is in volts, power is in mW, and current is
in mA.
Value The value of the measurement.
Low Warning The lower limit for the warning threshold.
High Warning The higher limit for the warning threshold.
Low Alarm The lower limit for the alarm threshold.
High Alarm The higher limit for the alarm threshold.