show
show.port.exit
Syntax exit destDomainID sourcePort
Purpose This command displays the exit port from a source port to a given
destination domain. This command shows the preferred path
configuration.
Use all for one of the command’s parameters to display all configured
and actual exit ports for either the destination domain ID or the
specified source port. You cannot specify all for both parameters. If
the destination domain is set to all, then all paths from the specified
source port are displayed. If the source port is set to all, the output
shows all source port paths to the specified domain.
Parameters This command has the following parameters:
destDomainId Specifies the destination domain ID. Valid domain
IDs are in the range 1–31, or, use all to show all exit
ports to and from the source port specified in the
sourcePort parameter.
sourcePort Specifies the number of the source port. Valid port
numbers values are:
0–11 for the Sphereon 4300
0–15 for the Sphereon 3016 and 3216
0–15 for the Sphereon 4400
0–23 for the Sphereon 4500
0–31 for the Sphereon 4700
0–31 for the Sphereon 3032 and 3232
0–31 for the ED-5000
0–63 for the Intrepid 6064
0–127 and 132–143 for the Intrepid 6140
Or, you can specify all to show all exit ports to the
destination domain ID specified for the destDomainId
parameter.