Specifications
58 Getting Started with the McDATA Intrepid FICON Director
Figure 5-15 Add device to Switch Binding membership list
The last step is to activate the changes by selecting the
Activate button.
To remove a device from the list, Switch Binding must first be disabled.
5.5 Port configuration
This section describes how to configure ports, port names, port binding, port type, port
speed, blocked or unblocked, state and enable, or disable long-distance buffering.
5.5.1 Defining Nicknames
Each port is initially identified by a WWN, which is an 8-byte hexadecimal number. Assigning
a meaningful Nickname to a port or node makes it easier to identify a device when it is
connected to the port:
1. In the EFC Manager window double-click the icon of the
Director where you want to
configure the ports.
2. A new window opens displaying the Hardware view of the Director. Click the
Node List
tab. A list of all connected devices is displayed as shown in Figure 5-16. The WWN and
the Unit Type are automatically retrieved from the device connected to the port.
Note: Switch Binding cannot be disabled while Enterprise Fabric Mode is active and the
Director is online.
Checked after adding