Event Code Tables
Event Code: 516
Message: SFP/XFP optics digital diagnostics alarm threshold exceeded.
Severity: Minor.
Explanation: A digital diagnostics warning threshold is exceeded. If warning condition persists, additional 516 events are
generated.
Action: Replace the failed transceiver with a functional transceiver of the same type.
Event Data: Byte 0 = port number.
Byte 2 = type of optics: Bit 1 =SFP;Bit2 =XFP.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 536
Message: Internal frame error - port anomaly threshold exceeded.
Severity: Minor.
Explanation: The 24 hour internal frame error threshold for the indicated port was exceeded.
Action: Monitor the performance of the port module (and associated port modules). If persistent resets occur, or if other
system errors are recorded against the module, replace the indicated UPM with a functional UPM of the same
type. Perform the data collection procedure and return the CD and faulty card to McDATA support personnel.
Event Data: Byte 0 = port number. Bytes 17 and 18 = transmitter technology.
Byte 1 = engineering reason code. Byte 19 = distance capabilities.
Bytes 4 - 7 = elapsed millisecond tick count. Byte 20 = supported transmission media.
Bytes 8 - 11 = reason code specific. Bytes 21 and 22 = speed capability and configuration.
Byte 16 = connector type.