Service manual

A
A-48
Intrepid® 6064 Director Installation and Service Manual
Event Code Tables
Event Code: 450
Message: Serial number mismatch detected.
Severity: Informational.
Explanation: This event occurs when the sequence number or OEM serial number in the system VPD (read from the
backplane) does not match the sequence number and serial number that was saved in NVRAM the last time the
director was IPLed. This event will occur normally when a CTP is moved from one director to the master position
of another director. This event may occur abnormally when a hardware problem causes a problem reading the
system VPD from the backplane.
Action: None. Any configured feature keys will be cleared. Configuration information will be synched with the backplane
VPD, and the CTP will automatically be IPLed.
Event Data: Bytes 0 - 12 = sequence number from the system VPD.
Bytes 13 - 31 = OEM serial number from the system VPD.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 451
Message: Switch speed incompatibility detected.
Severity: Informational.
Explanation: This event occurs when the configured director speed saved in NVRAM conflicts with the speed capability of the
director. This event may occur when backup CTP hardware running an early version of software (below version
1.3) is improperly synchronized with a CTP operating at greater than 1 Gbps.
Action: None. Director speed configuration and port speed configuration data will be set to a level that is compatible with
the CTP, and the CTP will automatically be IPLed.
Event Data: None.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED