Service manual
5
5-42
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
— If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16” door tool into
the socket hole at the right top of the front door. Turn the tool
counter-clockwise to unlock and open the door. Repeat this
step to open the rear door.
— If the director is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet front door as directed by
the customer representative. Repeat this step to open the rear
door.
4. Power off and unplug the director (Power-Off Procedure on
page 4-35).
DANGER
Disconnect the power cords.
5. If necessary, record the director serial number.
6. Follow ESD procedures by attaching a wrist strap to an approved
bench grounding point and your wrist.
ATTENTION! To avoidcausing machine errorsor damagewhileworkingon
the director, follow ESD procedures by connecting a grounding cable to an
approved bench grounding point and wearing an ESD wrist strap.
7. Unseat and disconnect all logic cards (CTP2 and port cards) from
the backplane. Unseat the cards only, do not remove them from
the directorchassis. Inaddition, do notdisconnect the Ethernet or
fiber-optic cables. For each logic card:
a. Insert the torque tool into the locking Allen screw at the
bottom of the card. Turn the screw counter-clockwise until the
spring releases and the tool turns freely.
b. Insert the torque tool into the Allen screw at the top of the
card. To unseat the card and cam it out of the backplane, turn
the screw counterclockwise until the tool turns freely.
c. Disconnect thecard from thebackplane bypulling itout ofthe
card track approximately two inches.
8. Unseat and disconnect (but do not remove) both power supplies
(RRP: Power Supply on page 5-24).
9. Remove the RFI shield (RRP: RFI Shield on page 5-28).