Service manual
5
RRP: Port Module Card (UPM)
5-17
Removal and Replacement Procedures (RRPs)
b. Verify portcard information (FRUname, position, and state)is
correct.
If a problem is indicated, go to Chapter 3, Maintenance Analysis
Procedures (MAPS) to isolate the problem.
10. Restore communication to the replacement port card and set the
card online as directed by the customer (Downloading Director
Firmware and Software on page 4-41). Inform the customer the port
card is available for use.
11. Perform the data collection procedure (Collecting Maintenance
Data on page 4-32).
12. Perform one of the following to clear the system error (ERR) LED:
— If at the management server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click the Clear System Error Light menu selection.
— If at a web browser connected to the EFCM Basic Edition
interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with
the Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
13. If necessary, close and lock the equipment cabinet door.