Service manual

5
5-12
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
13. If the customer requests the replacement CTP2 card be set as the
active card, perform a FRU switchover. At the Hardware View,
right-click the graphic representing the replacement card to open
amenu,thenselectSwitchover.
14. Perform one of the following to clear the system error (ERR) LED:
If at the management server, open the Hardware View and:
a. Right-click the front panel bezel graphic (away from a
FRU) to open a menu.
b. Click the Clear System Error Light menu selection.
If at a web browser connected to the EFCM Basic Edition
interface:
a. Click the Switch tab at the Operations panel. The Operations
panel opens with the Switch page displayed.
b. Click the Sys Err Light tab. The Switch page displays with
the Sys Err Light tab selected. A System Error Light is ON
message displays on the page.
c. Click Clear Light.
15. If necessary, close and lock the equipment cabinet door.