Service manual
5
5-6
Intrepid® 6064 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
RRP: Cable Management Assembly
Use the following procedures to remove or replace the cable
management assembly at the front of the director. A list of tools
required is provided.
Tools Required A door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet) is required to perform these
procedures.
Removal To remove the cable management assembly:
1. If the director is installed in a stand-alone configuration, go to
step 2. If the director is rack-mounted, perform one of the
following:
— If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16" door tool into
the socket hole at the right top of the front door. Turn the tool
counter-clockwise to unlock and open the door.
— If the director is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet front door as directed by
the customer representative.
2. If fiber-optic and Ethernet cables are attached to the director,
disengage the cables from the cable management assembly, then
lift the cables up and out of the assembly.
3. Two captive pins secure the assembly to the chassis (Figure 5-3).
Pull both pins inward to release the assembly, then pull the
assembly away from the front of the director.