Service manual

5
Removing and Replacing FRUs
5-5
Removal and Replacement Procedures (RRPs)
Concurrent FRUs
Table 5-2 lists the concurrent FRUs. Concurrent FRUs are removed
and replaced while the director is powered on and operational. The
table also lists ESD precautions (yes or no) for each FRU, and
references the page number of the removal and replacement
procedure.
Nonconcurrent FRUs
Table 5-3 lists the nonconcurrent FRUs. Nonconcurrent FRUs are
removed and replaced after the director is powered off. The table also
lists ESD precautions (yes or no) for each FRU, and references the
page number of the removal and replacement procedure.
Table 5-2 Concurrent FRUs
Concurrent FRU Name ESD Precaution Requirement Page
Cable management assembly No 5-6
Control processor (CTP2) card Yes 5-8
Universal port module (UPM) card Yes 5-13
Small form factor pluggable (SFP) optical transceiver Tes 5-18
UPM filler blank No 5-22
Power supply Yes 5-24
Radio frequency interference (RFI) shield No 5-28
Serial crossbar (SBAR) assembly Yes 5-29
Fan module Yes 5-33
Table 5-3 Nonconcurrent FRUs
Nonconcurrent FRU Name ESD Precaution Requirement Page
Power module assembly Yes 5-37
Backplane Yes 5-41