Table 3-5 SNMP Alerts or Alarm Definitions
Figure 3-5 shows an illustration of the Trap Viewer utility which is
shipped with Sanvergence manager.
Alert or Alarm Name Description
Cold Start The SAN Router is powered on, or rebooted. Informational
only message, no action required.
Link Down A port interface loses an active link signal.
Link Up A port interface acquires an active link signal.
flashNewImageInstallTrap A new firmware image is installed in flash memory.
Informational only message, no action required.
envVoltageUpperThreshTrap The upper voltage threshold is exceeded. This message
indicates that there may be a problem with the power
supplies or the router.
envVoltageLowerThreshTrap The power voltage is less than the lower voltage threshold.
This message indicates that there may be a problem with
the power supplies or the router.
envTempUpperTrap The upper temperature threshold is exceeded. This
message indicates that there may be a problem with the
power supplies or the router.
ChasFanStatusTrap The state of the fan changes. This message indicates there
may be a problem with the power supplies (the fans are part
of the power supply units.)
ChasPowerSupplyStatusTrap The status of power changes from down to up or vice versa.
This message indicates there is a problem with a power
supply.
connUnitPortStatus Change The overall status of a port that has changed. This
message indicates there may be a problem with a port or a
link is no longer active.
connUnitStatusChange The overall status of the SAN Router that has changed.