Service manual

Installing and Connecting the 2640 SAN Router
2-15
Cable Guidelines
ATTENTION! Review and implement the following cable guidelines to
avoid signal interference or cable damage.
Use RJ45 cable for the Network Management port.
Use DB9 null modem cable for the console port.
Confirm you have appropriate cables to attach the devices, for
example the server and targets.
Do not bend fiber optic cables to a radius smaller than three (3)
inches. Doing so could result in serious degradation in
performance or complete loss of connectivity.
Do not lay copper cables near transformers or alongside power
cables for any distance. Doing so could introduce noise into the
signaling.
Avoid laying cables near sharp edges or where objects or other
equipment can crush them.
Laser types at each end of any link must match.
Table 2-6 Compatible Cable Types
Type of Cable Range SFP Type
62.5 um Multi-Mode Fiber Optic
FC/GE
2-300 m Short wave
laser
50 um Multi-Mode Fiber Optic
FC/GE
2-500 m Short wave
laser
9 um Single Mode Fiber Optic 2m-10 Km Long wave
laser
Copper 0-30 m (equalized cable)
0-10 m (unequalized cable)
Copper (FC
HSSDC2)