Installation Tasks
2-21
Installation Tasks
2. Select Ports and RX BB_Credit from the Configure menu at any
view. The RX BB_Credit View displays.
3. Perform one of the following:
To set all offline ports to default values, click Default.
To setanofflineport toa user-specifiedvalue, typethe desired
value in the RX BB_Credit column.
4. Click OK to save and activate changes.
5. Set ports online (Blocking and Unblocking Ports on page 4-27 ).
Configure Port NPIV
NPIV allows multiple (up to 256) Fibre Channel addresses to be
assigned to a node (N_Port). The NPIV feature must be installed
(Install PFE Keys (Optional) on page 2-25). Perform this procedure to
configure ports for NPIV connectivity.
1. Select Ports and NPIV from the Configure menu at any view. The
NPIV View displays.
2. Click Enable to activate director NPIV operation.
3. To set a port to a user-specified value, type the desired value (1
through 256)intheLogin column.
4. Click OK to save and activate changes.
Configure SNMP
Perform this procedure to configure names, write authorizations,
addresses, and user datagram protocol (UDP) port numbers for
SNMP trap message recipients. To configure recipient workstations:
1. Select SNMP from the Configure menu at any view. The SNMP
View displays (Figure 2-10).