Service manual
2
2-20
Intrepid® 6140 Director Installation and Service Manual
Installation Tasks
c. Click the check box in the FAN column toenable or disable the
fabric address notification (FAN) feature (default is enabled).
A check mark in the box indicates FAN is enabled. When the
feature is enabled, the port transmits FAN frames after loop
initialization to verify that FC-AL devices are still logged in.
d. Selectfromthe drop-down listin the Type column to configure
the port type. Available selections are fabric port (F_Port),
expansion port (E_Port), generic port (G_Port), generic mixed
port (GX_Port), and fabric mixed port (FX_Port).
e. Select from the drop-down list in the Speed column to
configure the port transmission rate. Available selections are
auto-negotiate between 1.0625 and 2.1250 gigabit per second
(Gbps) operation (Negotiate), 1.0625 Gbps operation (1
Gb/sec), and 2.1250 Gbps operation (2Gb/sec).
2. Click OK to save and activate changes.
Figure 2-9 Basic Information View
Configure Port BB_Credit
Perform this procedure to configure port receive BB_Credit.
1. Set all or a subset of user-specified ports offline (Blocking and
Unblocking Ports on page 4-27).