Service manual

A
Thermal Events (800 through 899)
A-71
Event Code Tables
Event Code: 812
Message: CTP card shutdown due to thermal violation.
Severity: Major.
Explanation: A CTP card failed and was powered off because of excessive heat. This event follows an indication that the hot
temperature threshold was reached or exceeded (event code 811). If the active CTP card fails, the backup card
takes over operation. If the backup CTP card fails, the active card is not impacted.
Action: Replace the failed CTP card with a functional card. Perform the data collection procedure and return the CD and
faulty card to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 850
Message: System shutdown due to CTP card thermal violations.
Severity: Severe.
Explanation: The director powered off because of excessive thermal violations on the last operational CTP card.
Action: Replace the failed CTP card with a functional card. Perform the data collection procedure and return the CD and
faulty card to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident