Service manual

A
Thermal Events (800 through 899)
A-67
Event Code Tables
Thermal Events (800 through 899)
Event Code: 800
Message: High temperature warning (port module thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a UPM indicates the warm temperature threshold was reached or exceeded.
Action: Replace the indicated UPM with a functional UPM of the same type. Perform the data collection procedure and
return the CD and faulty card to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 801
Message: Critically hot temperature warning (port module thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a UPM indicates the hot temperature threshold was reached or exceeded.
Action: Replace the indicated UPM with a functional UPM of the same type. Perform the data collection procedure and
return the CD and faulty card to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident