SBAR Events (600 through 699)
A-65
Event Code Tables
Event Code: 619
Message: SBAR module ASIC reset.
Severity: Informational.
Explanation: System software detected an abnormal event associated with the SBAR. Recovery of the SBAR required system
software to perform a reset of the port module hardware.
Action: Monitor the performance of the SBAR. If persistent resets occur, or if other system errors are recorded against
the module, replace the indicated SBAR with a functional SBAR. Perform the data collection procedure and
return the CD and faulty card to McDATA support personnel.
Event Data: Byte 0 = SBAR slot position.
Byte 1 = engineering reset reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 620
Message: SBAR fan failure.
Severity: Informational.
Explanation: System software has detected the failure of one or more SBAR fan modules.
Action: No direct action required. System software continues monitoring the SBAR thermal status. In the event of a
detected thermal violation, subsequent 805, 806,or807 events will be posted.
Event Data: Bytes 0 - 3 = reserved.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 and 9 = failed SBAR fan count.
Bytes 10 and 11 = operational SBAR fan count.
Byte 12 - 15 = reserved.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident