Service manual
A
A-64
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 607
Message: Director contains no operational SBARs.
Severity: Severe.
Explanation: The director firmware does not recognize an installed SBAR.
Action: Install at least one functional SBAR and power-on reset (POR) the director.
Event Data: Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 608
Message: User initiated SBAR switch-over.
Severity: Informational.
Explanation: The backup SBAR has become the active SBAR at a user’s request. The previously active SBAR is now the
backup SBAR.
Action: No action required.
Event Data: There is no supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident