Service manual

A
A-62
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 602
Message: SBAR anomaly detected.
Severity: Informational.
Explanation: Director operational firmware detected a deviation in the normal operating mode or operating status of the
indicated SBAR.
Action: No action required. An event code 604 is generated if the SBAR fails.
Event Data: Byte 0 = SBAR slot position. Byte 12 = detecting port.
Byte 1 = anomaly reason code. Byte 13 = connected port.
Bytes 4 - 7 = elapsed millisecond tick count. Byte 14 = participating SBAR.
Bytes 8 and 9 = high-availability error callout #1. Bytes 16 and 17 = high-availability error callout #3.
Bytes 10 and 11 = high-availability error callout #2. Bytes 18 and 19 = high-availability error callout #4.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 603
Message: SBAR hot-removal completed.
Severity: Informational.
Explanation: An SBAR was removed with the director powered on and operational.
Action: No action required.
Event Data: Byte 0 = SBAR slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident