Service manual
A
Port Card (UPM and XPM) Events (500 through 599)
A-59
Event Code Tables
Event Code: 583
Message: Loss of signal or loss of synchronization.
Severity: Major.
Explanation: An attached OSI or FICON server recognized a loss-of-signal condition or a loss-of-synchronization condition
that persisted for more than the specified receiver-transmitter timeout value (R_T_TOV).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI)
or the FICON architecture document (FICON). If fault isolation at the server does not detect a failure, the problem
may be due to a port failure. See
MAP 0000: Start MAP
for instructions.
Event Data: Refer to the T11/99-017v0 or FICON architecture document for the specific link incident record format.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 584
Message: Not operational primitive sequence received.
Severity: Major.
Explanation: An attached OSI or FICON server received a not-operational primitive sequence (NOS).
Action: A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI)
or the FICON architecture document (FICON). If fault isolation at the server does not detect a failure, the problem
may be due to a port failure. See
MAP 0000: Start MAP
for instructions.
Event Data: Refer to the T11/99-017v0 or FICON architecture document for the specific link incident record format.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident