Service manual
A
A-50
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 502
Message: Port module anomaly detected.
Severity: Informational.
Explanation: The CTP card detected a deviation in the normal operating mode or status of the indicated four-port UPM.
Action: No action required. An event code 504 is generated if the UPM fails.
Event Data: Byte 0 = UPM slot position.
Byte 1 = engineering reason code.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 14 = participating SBAR.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 503
Message: Port card hot-removal completed.
Severity: Informational.
Explanation: A UPM was removed with the director powered on and operational.
Action: No action required.
Event Data: Byte 0 = UPM slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident