Service manual

1
1-12
Intrepid® 6140 Director Installation and Service Manual
General Information
transmission without interruption.Failover tothebackupassembly is
transparent to attached devices.
EachSBAR assemblyconsistsof acard and steelcarriagethat mounts
flush on the backplane. The carriage provides protection for the back
of the card, distributes cooling airflow, and assists in aligning the
assembly during installation. Therear of the carriage contains agreen
LED that illuminates if the assembly is operational and active, and an
amber LED that illuminates if the assembly fails. Both LEDs are
extinguished on an operational backup assembly. The amber LED
blinks if FRU beaconing is enabled.
Backplane
The backplane provides 48 VDC power distribution and connections
for all logic cards. The backplane is a nonconcurrent FRU. The
director must be powered off prior to FRU removal and replacement.
Error-Detection, Reporting, and Serviceability Features
The director provides the following error detection, reporting, and
serviceability features:
Light-emitting diodes (LEDs) on director FRUs and the front
bezel that provide visual indicators of hardware status or
malfunctions.
Redundant FRUs (logic cards, power supplies, and cooling fans)
that are removed or replaced without disrupting director or Fibre
Channel link operation.
A modulardesign thatenables quick removaland replacement of
FRUs without the use of special tools or equipment.
System alerts and logs that display director, Ethernet link, and
Fibre Channel link status at the management server (running a
SAN management application), client communicating with the
management server, or EFCM Basic Edition interface.
Diagnostic software that performs power-on self-tests (POSTs)
and port diagnostics (internal loopback, external loopback, and
Fibre Channel (FC) wrap tests). The FC wrap test applies only
whenthe directoris configuredto operate in FICONmanagement
style.