Service manual

A
A-38
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
CTPCardEvents(400through499)
Event Code: 400
Message: Power-up diagnostics failure.
Severity: Major.
Explanation: Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as indicated by the event data.
Action: Replace the failed FRU with a functional FRU. Perform the data collection procedure and return the CD and faulty
FRU to McDATA support personnel.
Event Data: Byte 0 = FRU code as follows: 01 = backplane, 02 =CTPcard,03 = SBAR, 05 = fan module,
06 = power supply, and 08 through 0F =UPMs.
Byte 1 = FRU slot number.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 410
Message: CTP card reset.
Severity: Informational.
Explanation: The indicated CTP card reset after a director power-on, CTP card installation, hardware IML (CTP card
faceplate), or software IPL. An IPL can be user-initiated at the management server application, or occur
automatically after a firmware fault (event code 411). The event data indicates the type of reset.
Action: No action required.
Event Data: Byte 0 = reset type as follows: 00 = power-on or CTP hot-insert, 02 =IML,04 =IPL,
40 = partition switch.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident