Service manual

A
Fan Module Events (300 through 399)
A-37
Event Code Tables
Event Code: 333
Message: Rear bottom fan tray removed.
Severity: Major.
Explanation: A fan module has been removed.
Action: Replace the fan module immediately.
Event Data: No supplementary data included with the event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 370
Message: Fan status polling temporarily disabled.
Severity: Minor.
Explanation: One or more fans are changing between failed or recovered status values beyond a threshold. One or more fans
may have failed. These conditions will re-enable fan status polling: an IPL/IML/POR, enabled hourly, fan insertion.
Action: No action required.
Event Data: No supplementary data included with the event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident