Service manual
A
A-32
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 304
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Five cooling fans failed or are rotating at insufficient angular velocity. The remaining fans are operational. The
amber LED illuminates at the rear of the fan modules associated with the failed fans.
Action: Replace the indicated fan modules.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 305
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Six cooling fans failed or are rotating at insufficient angular velocity. The remaining fans are operational. The
amber LED illuminates at the rear of the fan modules associated with the failed fans.
Action: Replace the indicated fan modules.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident