Service manual
A
A-30
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Fan Module Events (300 through 399)
Event Code: 300
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: One cooling fan failed or is rotating at insufficient angular velocity. The remaining fans are operational. The amber
LED illuminates at the rear of the fan module associated with the failed fan.
Action: Replace the indicated fan module.
Event Data: The first byte of event data (byte 0) specifies the failed fan number.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 301
Message: Cooling fan propeller failed.
Severity: Major.
Explanation: Two cooling fans failed or are rotating at insufficient angular velocity. The remaining fans are operational. The
amber LED illuminates at the rear of the fan modules associated with the failed fans.
Action: Replace the indicated fan modules.
Event Data: The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident