Service manual
A
A-26
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Power Supply Events (200 through 299)
Event Code: 200
Message: Power supply AC voltage failure.
Severity: Major.
Explanation: Alternating current (AC) input to the indicated power supply is disconnected or AC circuitry in the power supply
failed. The second power supply assumes the full operating load for the director.
Action: Ensure the power supply is connected to facility AC power, and verify operation of the facility power source. If the
AC voltage does not recover (indicated by event code 203), replace the failed power supply. Perform the data
collection procedure and return the CD and failed power supply to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 201
Message: Power supply DC voltage failure.
Severity: Major.
Explanation: Direct current (DC) circuitry in the power supply failed. The second power supply assumes the full operating load
for the director.
Action: Replace the failed power supply. Perform the data collection procedure and return the CD and failed power
supply to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident