Service manual
A
System Events (000 through 199)
A-3
Event Code Tables
System Events (000 through 199)
Event Code: 001
Message: System power-down.
Severity: Informational.
Explanation: The director was powered off or disconnected from the facility AC power source. The event code is distributed the
next time the director powers on, but the date and time of the code reflect the power-off time.
Action: No action required.
Event Data: No supplementary data included with the event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 010
Message: Login Server unable to synchronize databases.
Severity: Minor.
Explanation: Following a CTP card reset or replacement, the Login Server attempted to acquire an up-to-date copy of its
databases from the other CTP card, but failed. All fabric services databases are initialized to an empty state,
resulting in an implicit fabric logout of all attached devices.
Action: Perform the data collection procedure and return the CD to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident