Service manual

5
5-40
Intrepid® 6140 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
RRP: Backplane
Use the following procedures to remove or replace the backplane. A
list of tools required is provided.
Tools Required The following tools are required to perform these procedures.
Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
Torque tool and hex adapter (provided with the director).
Standard flat-tip screwdriver.
Standard cross-tip (Phillips) screwdriver.
ESD grounding cable and wrist strap.
Maintenance terminal (desktop or notebook PC) with:
The Microsoft Windows 98, Windows2000, Windows
Millennium Edition, or Windows NT 4.0 operating system.
RS-232 serial communication software (such as ProComm
Plus or HyperTerminal). HyperTerminal is provided with
Windows operating systems.
Asynchronous RS-232 null modem cable (provided with the
director).
Removal To remove the backplane:
1. At the Hardware View, double-click the graphic representing the
director bezel (do not click a graphical FRU) to open the Director
Properties dialog box. Record the director serial number. This
number must be programmed into the replacement backplane.
If the director is not communicating with the management server
(Director Properties dialog box is not available), obtain the serial
number while performing step 5.
2. Notify the customer that the director will be powered off. Ensure
the customer system administrator quiesces Fibre Channel frame
traffic through the director and sets attached devices offline.
3. If the director is installed in a stand-alone configuration, go to
step 4. If the director is rack-mounted, perform one of the
following: