Service manual
5
5-26
Intrepid® 6140 Director Installation and Service Manual
Removal and Replacement Procedures (RRPs)
RRP: AC Module
Use the following procedures toremove or replace the ACmodule. A
list of tools required is provided.
Tools Required The following tools are required to perform these procedures.
• Door key with 5/16-inch socket (provided with the FC-512
Fabricenter equipment cabinet).
• Standard cross-tip (Phillips) screwdriver.
• ESD grounding cable and wrist strap.
Removal To remove the AC module:
1. If the director is installed in a stand-alone configuration, go to
step 2. If the director is rack-mounted, perform one of the
following:
— If the director is installed in a McDATA-supplied FC-512
Fabricenter equipment cabinet, insert the 5/16" door tool into
the socket hole at the right top of the rear door. Turn the tool
counter-clockwise to unlock and open the door.
— If the director is installed in a customer-supplied equipment
cabinet, unlock and open the cabinet rear door as directed by
the customer representative.
DANGER
Disconnect the power cords.
ATTENTION! Do not remove the power cord from the operational AC
module.
2. Disconnect the power cord from the defective AC module.
ATTENTION! To avoidcausing machine errorsor damagewhileworkingon
the director, follow ESD procedures by connecting a grounding cable to the
director chassis and wearingan ESD wrist strap.
3. Follow ESD procedures by attaching a wrist strap to the director
chassis and your wrist (Figure 5-1).